NumerSpace

Categories

Finance & InvestmentHealth & FitnessWork & CareerTime & DateMarketing & AnalyticsMath & ConvertersEducation & ProductivityHome & LivingClothing & SizingPetsVehicle & TravelFaithAstrologyTax & BillsUnit Converters
Blog
TR EN
Türkçe oku
Home & Living

LED equivalent wattage chart: what replaces a 40, 60, 75 or 100 W bulb

To replace a 60 W incandescent, look for about 800 lumens, or 806 on EU boxes. Lumen chart by bulb size and how many watts an LED replacement draws.

Ali Yılmaz··7 min read
An incandescent bulb next to an LED bulb, labeled 60 W and 806 lumens

An LED equivalent wattage chart matches LED (light-emitting diode) bulbs to old incandescent bulbs by lumens, the amount of light they give, not by watts. To replace a 60 W incandescent bulb, look for an LED of about 800 lumens, or 806 on EU boxes.

The watts on the LED box tell you how much power the bulb uses, not how bright it is. That number depends on the bulb's efficiency, so two bulbs with the same lumens can draw different wattages.

The chart below covers standard bulbs that spread light in all directions, from 15 to 300 W. Spotlights follow different rules, covered near the end.

LED equivalent wattage chart from 15 to 300 W

The LED equivalent wattage chart below lists two sets of lumen values. The US column shows the ranges from the former Energy Star lamp specification. That document set how bright a bulb had to be before an Energy Star box could claim a given incandescent wattage. The EU and Great Britain column is the single value their labeling rules tie to each wattage.

The last column is an illustration, not a limit for every bulb. It shows the watts of a bulb with the lowest lumens in the range at 80 lumens per watt. That was the former Energy Star minimum for bulbs with a color rendering index below 90. Bulbs at 90 or above could qualify at 70.

Old incandescent bulb (W)Former Energy Star range, US (lumens)EU and Great Britain value (lumens)Watts at 80 lm/W, lowest lumens of the range
15Not listed136Not listed
25250–4492493.1
40450–7994705.6
60800–1,09980610.0
751,100–1,5991,05513.8
1001,600–1,9991,52120.0
1252,000–2,549Not listed25.0
1502,550–3,0002,45231.9
2003,001–3,9993,45237.5
3004,000–6,000Not listed50.0

To use the chart, find your old bulb's wattage. For the same brightness, pick an LED close to the lumens at the start of that row's range, or to the EU value. For a brighter room, pick more lumens. A brighter bulb in the same range also draws more watts at the same efficacy.

Energy Star ended its lamp and luminaire specifications on December 31, 2024. The US ranges are therefore a former certification rule that many charts still reuse, not a current requirement.

What to check on the box

Read the box in this order:

  • Lumens: for the same brightness, stay close to the lumens for your old bulb's wattage. Pick more lumens for a brighter room.
  • Watts: these set the running cost. The electricity bill calculator turns watts and hours of use into a monthly cost, and the household appliance electricity guide shows how lighting compares with other devices.
  • Lumens per watt: divide lumens by watts with a basic calculator to compare efficiency between boxes.
  • Base and dimming: check that the base fits your socket. If the fixture has a dimmer, check that the box calls the bulb dimmable. EU and British rules require boxes to show the cap type and to warn when a bulb cannot be dimmed.
  • Equivalent wattage: treat it as a hint. Boxes that follow the former US ranges and EU boxes can print different equivalents for the same lumens.
  • Light appearance and color rendering index (CRI): these set the color of the light and how true colors look. The lighting calculator page explains which values suit each room.

The same calculator also works out the total lumens a room needs from its floor area. Divide that total by the lumens per bulb to get the bulb count. A room that needs 4,000 lumens takes five 800-lumen bulbs.

How many watts an LED replacement draws

An LED replacement's wattage equals its lumens divided by its efficacy in lumens per watt. Hypothetical example: a box that lists 800 lumens and 8 W describes a bulb of 100 lumens per watt.

In the US, the Department of Energy's efficiency standard for general service lamps sets two limits on that efficacy. Since July 25, 2022, bulbs below 45 lumens per watt cannot be sold. As of November 2026, bulbs made on or after July 25, 2028 face a stricter minimum that rises with brightness.

Both limits cover bulbs from 310 to 3,300 lumens. The 2028 columns use the formula for integrated omnidirectional lamps shorter than 45 inches without standby mode, which describes a standard screw-in LED bulb.

Old bulb (W)Lumens, lowest in the former Energy Star rangeMax watts under the sale rule since July 25, 2022 (45 lm/W)Minimum efficacy, bulbs made from July 25, 2028 (lm/W)Max watts, bulbs made from July 25, 2028
4045010.0108.64.1
6080017.8124.36.4
751,10024.4127.58.6
1001,60035.6128.312.5

The 45 lm/W sale rule is loose for LEDs. Ordinary incandescent bulbs cannot meet it, since the EU reference values imply only about 9 to 17 lumens per watt for them. The 2028 rule is the limit that actually tightens LED wattage.

Even at the sale limit in force since July 2022, an 800-lumen LED draws about 70% less power than a 60 W incandescent. Over the same hours of use it also uses that much less energy. You can test other pairs with the percentage calculator.

Checking the divide-by-seven rule

Volt Lighting's lumens-to-watts guide suggests dividing the old incandescent wattage by 7 for a rough LED equivalent. For a 60 W bulb the rule gives 8.6 W.

At 800 lumens, 8.6 W means about 93 lumens per watt.

That efficacy sits between the former Energy Star minimum and the 2028 standard. A bulb built to the 2028 rule gives the same light on about 6.4 W, so the rule overstates the watts of newer bulbs. Lumens on the box remain the better guide.

Why US charts say 800 lumens and EU charts say 806

US and EU charts disagree because they come from different systems. The former Energy Star rule gave each wattage a lumen range. EU law gives each wattage one value and fills the gaps by linear interpolation. The EU energy labeling regulation then rounds the claimed wattage to the nearest whole watt.

Take a 1,000-lumen bulb. Under the former Energy Star rule it would have fallen in the 60 W range. Under EU rules its equivalent works out to 72 W. The steps below show the interpolation, and the ratio calculator can set up the same proportion.

StepCalculationResult
1. Neighboring rows1,000 lm lies between 806 and 1,055 lm60 W and 75 W
2. Lumens above the lower row1,000 − 806194 lm
3. Share of the gap194 ÷ 249 (lumen gap between the rows)0.779
4. Watts to add0.779 × 15 (watt gap between the rows)11.69 W
5. Incandescent equivalent60 + 11.69, rounded to a whole watt72 W

The 72 W is the incandescent bulb this LED replaces, not the power the LED draws. Under Energy Star the same bulb could have claimed at most 60 W. When you compare boxes from different markets, compare lumens.

Reading the Lighting Facts label

The Lighting Facts label is the brightness and energy panel that the Federal Trade Commission (FTC) requires on US bulb packages. Under the FTC labeling rule, the front of the package must show brightness in lumens and an estimated yearly energy cost with equal prominence. The cost assumes 3 hours of use a day at 11 cents per kWh.

The Lighting Facts panel on the side or back lists brightness, yearly energy cost, life in years, light appearance and the energy used in watts. Its light appearance scale runs from 2,600 K on the warm end to 6,600 K on the cool end.

The rule bars any other marks from that panel. An incandescent-equivalent claim, if the box carries one, sits elsewhere on the package. The bulb itself must also be marked with its lumens.

Buying bulbs in the EU or Great Britain

EU law and Great Britain's own lighting products regulations of 2021 tie a 60 W equivalence claim to 806 lumens. Both use the same table of values.

EU ecodesign rules also cap the power of each bulb, and the British regulations use the same formula. A standard non-smart LED giving 806 lumens with a CRI of 80 may draw at most about 8.9 W.

The cap rises with brightness, so a 1,521-lumen bulb, the 100 W equivalent, may draw up to about 15.3 W.

The EU energy label grades efficacy from A to G. The table shows what each class means in watts for a standard 806-lumen bulb, the 60 W equivalent.

EU energy classEfficacy (lm/W)Watts for 806 lumens
A210 or more3.8 or less
B185–2103.8–4.4
C160–1854.4–5.0
D135–1605.0–6.0
E110–1356.0–7.3
F85–1107.3–9.5
Gbelow 85above 9.5

The watt bands are rounded, so neighboring classes share an end value. For a bulb near a boundary, divide its lumens by its watts and compare the result with the efficacy column.

The power cap also cuts off the top of class F. A standard non-smart 806-lumen bulb with a CRI of 80 cannot exceed 8.9 W. On the EU market since September 1, 2021, such a bulb therefore cannot fall into class G.

Older EU boxes followed a different rule. Until September 2021, an earlier EU regulation based a 60 W claim on 741 lumens for a compact fluorescent bulb and 806 for an LED. That gap came from the claim rule, not from measuring two bulbs.

Spotlights, three-way and smart bulbs

Spotlights and other reflector bulbs use separate equivalence rules. For many reflector types, Energy Star required lumens of at least ten times the incandescent wattage. A 40 W reflector replacement therefore needed at least 400 lumens.

Three-way bulbs were judged at their brightest setting, so a 100 W three-way replacement needed 1,200 to 1,999 lumens. Smart bulbs that sit in standby mode get a lower efficacy target under the 2028 federal formula. EU rules give connected bulbs a small extra power allowance as well.

Related Tools

Lighting Calculator
Lumens and bulb count needed for room size
Electricity Bill Calculator
Device power, usage time and energy cost
A TV with its diagonal marked and a tape measure, illustrating TV dimensions
Home & Living

TV dimensions chart: screen width and height by TV size

TV dimensions chart with width and height for 32 to 98 inch 16:9 screens, the formula behind it, and how to check a TV against your wall or console.

Cutaway house with household appliances connected to an electricity meter
Home & Living

How much electricity do household appliances use?

Learn how to estimate each appliance's monthly kWh with watts × hours or the EnergyGuide label, with worked examples at the current U.S. average rate.

How much does 1 litre of paint cover: coverage table by surface type
Home & Living

How Much Paint Do I Need? m² Coverage Calculator Guide

Real-world paint coverage by surface type, step-by-step room paint calculation, and tips to avoid running short. From smooth plaster to concrete.

Floor plan, laser measure and house keys on a desk, for net vs gross square meters
Home & Living

Net vs Gross Square Meters: What's the Difference When Buying a Home?

Not sure what you're actually paying for? Learn the difference between net and gross square meters, how to calculate usable space, and avoid costly mistakes when buying a home.

What size TV should I buy: ideal TV screen size guide by room size
Home & Living

What Size TV Should I Buy? The Complete TV Screen Size Guide

The answer to 'what size TV should I buy' is right here. TV size calculator by viewing distance, 4K resolution guide, and room-by-room TV size recommendations, all in one place.

Ali Yılmaz: Ali Yılmaz is NumerSpace's editorial identity, writing about finance, health, units of measurement, time and everyday calculations. Every article's figures and sources are verified before publication.